Product Details

Wash Cup Setup, incl. 2-Channel Volumetric Pump, Wash Cup PEEK, Tubing, Solvent Bottles

PAL3-ActWashCup-2ChV

Wash Cup Setup, consisting of:
1 pc 2-Channel Volumetric Pump incl PAL Bus Connection cable
1 pc Wash Cup PEEK
1 pc PFA Transfer tube 1/16" for up to 850 mm
2 pcs Solvent Bottle 1000 ml
2 pcs Solvent Inlet Tubing Kit PFA

Attention: For x-rails longer than 850 mm PAL3-TubeLC/MS-VP-X is required (to be ordered separately)


Requires PAL Series II with FW 4.12 or higher
PAL3-ActWashCup-2ChV

Related Products

PAL3-TH-SLCMS-AWC-100

PAL3-TH-SLCMS-AWC-100

PAL System LC/MS Setup for 100 µl Smart Syringes, Needle Length 51 mm,
including 2-Channel Volumetric Pump, Wash Cup PEEK
PAL3-TH-SLCMS-AWC-250

PAL3-TH-SLCMS-AWC-250

PAL System LC/MS setup for 250 µl Smart Syringes, Needle Length 51 mm, including 2-Channel Volumetric Pump, Wash Cup PEEK

Spare parts

PAL3-VolPump-CV-2Ch

PAL3-VolPump-CV-2Ch

Check Valve Set for 2-Channel Volumetric LC/MS Pump
PAL3-VolPump-Seal-2Ch

PAL3-VolPump-Seal-2Ch

Piston Seal Replacement Part for 2-Channel Volumetric LC/MS Pump
PAL3-VolPump-Pist-2Ch

PAL3-VolPump-Pist-2Ch

Piston Seal assembly for 2-Channel Volumetric LC/MS Pump
PAL3-WashCup-G22

PAL3-WashCup-G22

PAL System Wash Cup for Injection Valves
PAL3-LCMS100VP-PFCFr-S

PAL3-LCMS100VP-PFCFr-S

Upgrade Kit for PFAS analysis
for PAL LC/MS Tool with 2-Channel Volumetric Pump and 100 µl Loop for up to 850 mm Systems
PAL3-LCMS100VP-PFCFr-X

PAL3-LCMS100VP-PFCFr-X

Upgrade Kit for PFAS analysis
for PAL LC/MS Tool with 2-Channel Volumetric Pump and 100 µl Loop for up to 1200 mm Systems
PAL3-LCMS250VP-PFCFr-S

PAL3-LCMS250VP-PFCFr-S

Upgrade Kit for PFAS analysis
for PAL LC/MS Tool with 2-Channel Volumetric Pump and 250 µl Loop for up to 850 mm Systems
PAL3-LCMS250VP-PFCFr-X

PAL3-LCMS250VP-PFCFr-X

Upgrade Kit for PFAS analysis
for PAL LC/MS Tool with 2-Channel Volumetric Pump and 250 µl Loop for up to 1200 mm Systems
PAL3-TubeLCMS-VP

PAL3-TubeLCMS-VP

Tubing for Connection between LC/MS Tool and Volumetric Pump, PFA, for up to 850 mm PAL Systems
PAL3-TubeLCMS-VP-X

PAL3-TubeLCMS-VP-X

Tubing for connection between LC/MS Tool and Volumetric Pump, PFA, for up to 1200 mm PAL Systems
PAL3-LCMSLoop

PAL3-LCMSLoop

Holding Loop (FEP) 100 µl for PAL LC/MS Tool
PAL3-DilAspKit

PAL3-DilAspKit

Solvent Inlet Tubing Kit PFA for
PAL System Dilutor and LC/MS

Related Content

Automated Sample Prep Workflows: Save money and time
eBooks
Automated Sample Prep Workflows: Save money and time
Automated Sample Prep Workflows: Save money and time
Automated Sample Prep Workflows: Save money and time
Automated Sample Prep Workflows: Save money and time
Automated Sample Prep Workflows: Save money and time

Automated Sample Prep Workflows: Save money and time

This compendium on instrumental sample preparation showcases the many proven solutions of automated sample preparation workflows for food, environmental, pharma, life science analysis, and beyond. 

PFAS Webinar
Webinars
Advancing PFAS Analysis - Robotic Automation and Streamlined LC/MS Workflows
Advancing PFAS Analysis - Robotic Automation and Streamlined LC/MS Workflows
Advancing PFAS Analysis - Robotic Automation and Streamlined LC/MS Workflows

Advancing PFAS Analysis - Robotic Automation and Streamlined LC/MS Workflows

To support the scientific community and advance PFAS analysis we are proud to offer a webinar on this topic.

Key topics:

  • PFAS Fundamentals: Learn about the chemistry and significance of PFAS compounds.
  • Sample Preparation Challenges: Understand current hurdles, regulations and best practices in PFAS extraction and purification.
  • Automated LC/MS Workflows: Get an overview on automated workflows and see how PAL System integrates with LC/MS to optimize sample preparation and injection.
  • Deep Dive: Explore online SPE for PFAS analysis.
Automated Sample Preparation webinar
Webinars
Automated Sample Preperation for LC/MS and GC/MS - Solutions for Food and Environmental Analysis
Automated Sample Preperation for LC/MS and GC/MS - Solutions for Food and Environmental Analysis

Automated Sample Preperation for LC/MS and GC/MS - Solutions for Food and Environmental Analysis

In this presentation we want to discuss an important development and a demand from analytical laboratories about the standardization and the automation of sample preparation procedures for food safety, environmental, the forensic or pharmaceutical analysis.

Presented by:
Hans-Joachim Huebschmann, PhD

Automated MALDI-TOF MS Workflows for Streamlined Bacterial Identification
Application Notes
Automated MALDI-TOF MS Workflows for Streamlined Bacterial Identification
Automated MALDI-TOF MS Workflows for Streamlined Bacterial Identification
Automated MALDI-TOF MS Workflows for Streamlined Bacterial Identification

Automated MALDI-TOF MS Workflows for Streamlined Bacterial Identification

This application note demonstrates the successful automation of two sample preparation workflows, Formic Acid (FA) and Beads method, for bacterial identification using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS).

Automated Direct Derivatization and GCMS Analysis
Application Notes
Automated Direct Derivatization and GCMS Analysis
Automated Direct Derivatization and GCMS Analysis

Automated Direct Derivatization and GCMS Analysis

A Robust Method for Comprehensive Metabolomic Profiling of Dried Blood Spots, Serum, and Plasma

PAL3 Thermal Mixer
Brochures
PAL3 Thermal Mixer
PAL3 Thermal Mixer
PAL3 Thermal Mixer

PAL3 Thermal Mixer

PAL3 Thermal Mixer – Temperature controlled heating and
mixing for well plates to boost your sample prep efficiency.

Minimize PFAS Background with PAL System Upgrade Kits
Brochures

Minimize PFAS Background with PAL System Upgrade Kits

Equip your PAL Systems for PFAS Analysis with Upgrade Kits and minimize PFAS Background.

Fully Automated Sample Preparation and Untargeted 2D-LC-Mass Spectrometry Workflow for Glycerophospholipid Analysis in Plasma
Posters
Fully Automated Sample Preparation and Untargeted 2D-LC-Mass Spectrometry Workflow for Glycerophospholipid Analysis in Plasma

Fully Automated Sample Preparation and Untargeted 2D-LC-Mass Spectrometry Workflow for Glycerophospholipid Analysis in Plasma

We developed an integrated workflow combining HILIC-LC-SWATH-MS for quantitative analysis and 2D-LC HILIC x RPLC DDA-EAD/MRMHR-EAD for qualitative characterization of complex lipidomes,particularly glycerophospholipids.

Untargeted 2DxLC-Mass Spectrometry using SWATH-DIA-Based Workflow for the Characterization of Lipid Profiles in Plasma Samples
Posters
Untargeted 2DxLC-Mass Spectrometry using SWATH-DIA-Based Workflow for the Characterization of Lipid Profiles in Plasma Samples
Untargeted 2DxLC-Mass Spectrometry using SWATH-DIA-Based Workflow for the Characterization of Lipid Profiles in Plasma Samples

Untargeted 2DxLC-Mass Spectrometry using SWATH-DIA-Based Workflow for the Characterization of Lipid Profiles in Plasma Samples

The use of lipidomic analyses based on LC-mass spectrometry has become widespread due to its sensitivity and specificity which provides a broader picture of lipid profiles in biofluids. In this work, we combined an automated sample extraction and a two-dimensional liquid chromatography (2DxLC) system with HILIC-based class separation followed by an orthogonal reverse-phase chromatography with an untargeted SWATH-DIA workflow to accurately annotate phosphatidylcholines (PC), lysophosphatidylcholine (LPC) and etherphosphatidylcholines (PC O-) in human plasma samples.

Contact