PAL System Smart SPME Arrow C-WR/PDMS 1.50 mm, wide sleeve, phase thickness 120 µm

SARR15-C-WR-120/20-P1

Smart SPME Arrow 1.50 mm wide sleeve
C-WR/PDMS (Carbon Wide Range / Polydimethylsiloxane)
phase thickness 120 µm
phase length 20 mm
color code light blue
pack of 1 pc
SARR15-C-WR-120-20

Related Products

PAL3-SPME-SArr-Kit

PAL3-SPME-SArr-Kit

PAL System Smart SPME Arrow Kit
PAL3-Agitator

PAL3-Agitator

PAL System Agitator
PAL3-AgiHeatex-Kit

PAL3-AgiHeatex-Kit

PAL System Agitator and Heatex Stirrer
PAL3-HeatexStirrer

PAL3-HeatexStirrer

PAL System Heatex Stirrer
PAL3-SPME-Eval-Mix

PAL3-SPME-Eval-Mix

SPME Performance Evaluation Mix
PAL3-SPME-ArrowCond

PAL3-SPME-ArrowCond

PAL System SPME Arrow Conditioning Module
ARR-Man-Inj-Kit

ARR-Man-Inj-Kit

PAL System Manual Injection Tool Kit for SPME Arrow and traditional SPME Fibers
PAL3-LowNdlGdeArr

PAL3-LowNdlGdeArr

PAL System Needle Guide Replacement for SPME Arrow Tool with Vial Transport Magnets
PAL3-SARR-Start-6890LCh

PAL3-SARR-Start-6890LCh

PAL System Smart SPME Arrow Starter Kit for Agilent GC 6890 with Large Charcoal Filter
PAL3-SARR-Start-6890Std

PAL3-SARR-Start-6890Std

PAL System Smart SPME Arrow Starter Kit for Agilent GC 6890 with Standard Assy
PAL3-SARR-Start-GC2010

PAL3-SARR-Start-GC2010

PAL System Smart SPME Arrow Starter Kit for Shimadzu GC 2010 Plus
PAL3-SARR-Start-GC2030

PAL3-SARR-Start-GC2030

PAL System Smart SPME Arrow Starter Kit for Shimadzu GC 2030
PAL3-SARR-Start-GC7890

PAL3-SARR-Start-GC7890

PAL System Smart SPME Arrow Starter Kit for Agilent GC 7890
PAL3-SARR-Start-GC8890

PAL3-SARR-Start-GC8890

PAL System Smart SPME Arrow Starter Kit for Agilent GC 8890 / 8860
PAL3-SARR-Start-Intuvo

PAL3-SARR-Start-Intuvo

PAL System Smart SPME Arrow Starter Kit for Agilent GC Intuvo
PAL3-SARR-Start-Tr1300

PAL3-SARR-Start-Tr1300

PAL System Smart SPME Arrow Starter Kit for Thermo GC Trace 1300/1310 and 1600/1610
PAL3-SARR-Start-TrUltra

PAL3-SARR-Start-TrUltra

PAL System Smart SPME Arrow Starter Kit for Thermo GC Trace Ultra
SARR-Man-Inj-Kit

SARR-Man-Inj-Kit

PAL System Manual Injection Kit for Smart SPME Arrow
ARR-Liner-CondModule

ARR-Liner-CondModule

Liner for PAL System SPME Arrow Conditioning Module
ARRLIN13-GC2010-3

ARRLIN13-GC2010-3

PAL System SPME Arrow Liner ID 1.3 mm for SHIMADZU GC 2010/GC 2030 SSL Injector
ARRLIN13-GC6890-3

ARRLIN13-GC6890-3

PAL System SPME Arrow Liner ID 1.3 mm, deactivated, for AGILENT GC 6890 SSL Injector
ARRLIN13-GC7890-3

ARRLIN13-GC7890-3

PAL System SPME Arrow Liner ID 1.3 mm, deactivated, for AGILENT GC 7890 SSL Injector
ARRLIN13-Trace1300-3

ARRLIN13-Trace1300-3

PAL System SPME Arrow Liner ID 1.3 mm, deactivated, for Thermo GC Trace 1300/1310/1600/1610 SSL Injector
ARRLIN17-GC2010-3

ARRLIN17-GC2010-3

PAL System SPME Arrow Liner ID 1.7 mm, deactivated, for SHIMADZU GC 2010/GC 2030 SSL Injector
ARRLIN17-GC6890-3

ARRLIN17-GC6890-3

PAL System SPME Arrow Liner ID 1.7 mm, deactivated, for AGILENT GC 6890 SSL Injector
ARRLIN17-GC7890-3

ARRLIN17-GC7890-3

PAL System SPME Arrow Liner ID 1.7 mm, deactivated, for AGILENT GC 7890 SSL Injector
ARRLIN17-Trace1300-3

ARRLIN17-Trace1300-3

PAL System SPME Arrow Liner ID 1.7 mm, deactivated, for Thermo GC Trace 1300/1310/1600/1610 SSL Injector
ARRLIN20-GC2010-3

ARRLIN20-GC2010-3

PAL System SPME Arrow Liner ID 2.0 mm, deactivated, for SHIMADZU GC 2010/ GC 2030 SSL Injector
ARRLIN20-TraceUltra-3

ARRLIN20-TraceUltra-3

PAL System SPME Arrow Liner ID 2.0 mm, deactivated, for Thermo GC Trace Ultra SSL Injector
SARR11-A-100-20

SARR11-A-100/20-P1

PAL System Smart SPME Arrow
Polyacrylate 1.10 mm, phase thickness 100 µm
SARR11-A-100-20

SARR11-A-100/20-P3

PAL System Smart SPME Arrow
Polyacrylate 1.10 mm, phase thickness 100 µm
SARR11-A-100-20

SARR11-A-100/20-P5

PAL System Smart SPME Arrow
Polyacrylate 1.10 mm, phase thickness 100 µm
SARR11-C-WR-120-20

SARR11-C-WR-120/20-P1

PAL System Smart SPME Arrow
C-WR/PDMS 1.10 mm, phase thickness 120 µm
SARR11-C-WR-120-20

SARR11-C-WR-120/20-P3

PAL System Smart SPME Arrow
C-WR/PDMS 1.10 mm, phase thickness 120 µm
SARR11-C-WR-120-20

SARR11-C-WR-120/20-P5

PAL System Smart SPME Arrow
C-WR/PDMS 1.10 mm, phase thickness 120 µm
SARR11-DVB-120-20

SARR11-DVB-120/20-P1

PAL System Smart SPME Arrow
DVB/PDMS 1.10 mm, phase thickness 120 µm
SARR11-DVB-120-20

SARR11-DVB-120/20-P3

PAL System Smart SPME Arrow
DVB/PDMS 1.10 mm, phase thickness 120 µm
SARR11-DVB-120-20

SARR11-DVB-120/20-P5

PAL System Smart SPME Arrow
DVB/PDMS 1.10 mm, phase thickness 120 µm
SARR11-DVB-CWR-120-20

SARR11-DVB/CWR120/20-P1

PAL System Smart SPME Arrow
DVB/C-WR/PDMS 1.10 mm, phase thickness 120 µm
SARR11-DVB-CWR-120-20

SARR11-DVB/CWR120/20-P3

PAL System Smart SPME Arrow
DVB/C-WR/PDMS 1.10 mm, phase thickness 120 µm
SARR11-DVB-CWR-120-20

SARR11-DVB/CWR120/20-P5

PAL System Smart SPME Arrow
DVB/C-WR/PDMS 1.10 mm, phase thickness 120 µm
SARR11-P-100-20

SARR11-P-100/20-P1

PAL System Smart SPME Arrow
PDMS 1.10 mm, phase thickness 100 µm
SARR11-P-100-20

SARR11-P-100/20-P3

PAL System Smart SPME Arrow
PDMS 1.10 mm, phase thickness 100 µm
SARR11-P-100-20

SARR11-P-100/20-P5

PAL System Smart SPME Arrow
PDMS 1.10 mm, Phase Thickness 100 µm
SARR1115-SEL5-S2

SARR1115-SEL5-S2

PAL System Smart SPME Arrow Selection Kit
SARR15-C-WR-120-20

SARR15-C-WR-120/20-P1

PAL System Smart SPME Arrow
C-WR/PDMS 1.50 mm, wide sleeve, phase thickness 120 µm
SARR15-DVB-120-20

SARR15-C-WR-120/20-P3

PAL System Smart SPME Arrow
C-WR/PDMS 1.50 mm, wide sleeve, phase thickness 120 µm
SARR15-DVB-120-20

SARR15-C-WR-120/20-P5

PAL System Smart SPME Arrow
C-WR/PDMS 1.50 mm, wide sleeve, phase thickness 120 µm
SARR15-DVB-120-20

SARR15-DVB-120/20-P1

PAL System Smart SPME Arrow
DVB/PDMS 1.50 mm, wide sleeve, phase thickness 120 µm
SARR15-DVB-120-20

SARR15-DVB-120/20-P3

PAL System Smart SPME Arrow
DVB/PDMS 1.50 mm, wide sleeve, phase thickness 120 µm
SARR15-DVB-120-20

SARR15-DVB-120/20-P5

PAL System Smart SPME Arrow
DVB/PDMS 1.50 mm, wide sleeve, phase thickness 120 µm
SARR15-DVB-CWR120-20

SARR15-DVB/CWR120/20-P1

PAL System Smart SPME Arrow
DVB/C-WR/PDMS 1.50 mm, wide sleeve, phase thickness 120 µm
SARR15-DVB-CWR120-20

SARR15-DVB/CWR120/20-P3

PAL System Smart SPME Arrow
DVB/C-WR/PDMS 1.50 mm, wide sleeve, phase thickness 120 µm
SARR15-DVB-CWR120-20

SARR15-DVB/CWR120/20-P5

PAL System Smart SPME Arrow
DVB/C-WR/PDMS 1.50 mm, wide sleeve, phase thickness 120 µm
SARR15-P-100-20

SARR15-P-100/20-P1

PAL System Smart SPME Arrow
PDMS 1.50 mm, wide sleeve, phase thickness 100 µm
SARR15-P-100-20

SARR15-P-100/20-P3

PAL System Smart SPME Arrow
PDMS 1.50 mm, wide sleeve, phase thickness 100 µm
SARR15-P-100-20

SARR15-P-100/20-P5

PAL System Smart SPME Arrow
PDMS 1.50 mm, wide sleeve, phase thickness 100 µm

Related Content

Online analysis of micropollutants on site with MS2Field
Posters
Online analysis of micropollutants on site with MS2Field

Online analysis of micropollutants on site with MS2Field

Robustness of SPME Arrow Immersion Sampling
Posters
Robustness of SPME Arrow Immersion Sampling
Robustness of SPME Arrow Immersion Sampling

Robustness of SPME Arrow Immersion Sampling

Fully automated SPME Arrow immersion technique with GC/MS analysis is an excellent option to analyze PAH compounds in drinking water; with higher throughput and robustness

Fully Automated Analysis of E-Cigarette Juice
Posters
Fully Automated Analysis of E-Cigarette Juice

Fully Automated Analysis of E-Cigarette Juice

Static headspace for the main volatiles and HS-SPME extraction are combined in one workflow for comprehensive analysis of main and trace components.

Sample Preparation Compendium
eBooks

Sample Preparation Compendium

Automated, Green, and Efficient
A Compendium on Micromethods in Analytical Sample Preparation

Discover robust, precise, and reliable analytical methods while following the principles of Green Analytical Chemistry in various fields such as Food & Food Safety, Environmental, Clinical, Life Science, and Chemical.

Automated Sample Prep Workflows: Save money and time
eBooks
Automated Sample Prep Workflows: Save money and time
Automated Sample Prep Workflows: Save money and time
Automated Sample Prep Workflows: Save money and time
Automated Sample Prep Workflows: Save money and time
Automated Sample Prep Workflows: Save money and time

Automated Sample Prep Workflows: Save money and time

This compendium on instrumental sample preparation showcases the many proven solutions of automated sample preparation workflows for food, environmental, pharma, life science analysis, and beyond. 

Flavor and Off-Flavour Analysis using Solid Phase Extraction webinar
Webinars
Flavor and Off-Flavor Analysis using Solid Phase Microextraction
Flavor and Off-Flavor Analysis using Solid Phase Microextraction

Flavor and Off-Flavor Analysis using Solid Phase Microextraction

Solid Phase Micro Extraction (SPME) is widely used for chemical analysis of foods, beverages and food contact materials. As an automated technique, the SPME applications are selected for their simplicity, throughput and extraction efficiency.  As a solvent-free extraction, it is gains even more importance today as a green analytic technique. Besides the traditional SPME Fiber, the new SPME Arrow is enhancing trace level sensitivity at high mechanical robustness. With these features, this presentation will give insight on SPME analysis in coffee, wine and off-flavors. 

Presented by:

Erich Leitner, Graz University of Technology Institute of Analytical Chemistry and Food Chemistry

Stefan Cretnik, PhD, Product Manager, CTC Analytics AG

Automated Sample Preparation webinar
Webinars
Automated Sample Preperation for LC/MS and GC/MS - Solutions for Food and Environmental Analysis
Automated Sample Preperation for LC/MS and GC/MS - Solutions for Food and Environmental Analysis

Automated Sample Preperation for LC/MS and GC/MS - Solutions for Food and Environmental Analysis

In this presentation we want to discuss an important development and a demand from analytical laboratories about the standardization and the automation of sample preparation procedures for food safety, environmental, the forensic or pharmaceutical analysis.

Presented by:
Hans-Joachim Huebschmann, PhD

SPME Arrow Webinar
Webinars
Robust and sensitive Analysis with PAL SPME Arrow
Robust and sensitive Analysis with PAL SPME Arrow

Robust and sensitive Analysis with PAL SPME Arrow

This webinar features practical aspects in the daily routine of SPME Arrow, and aspects for the comparison towards SPME Fibers. Application examples will include VOCs, PAHs, Fragrances and Off-flavours.

Presented by:
Stefan Cretnik, PhD, Product Manager, CTC Analytics AG

High-throughput Analysis of 1,4-Dioxane in Drinking Water using SPME Arrow–Trap with Multi-Step Enrichment
Application Notes
High-throughput Analysis of 1,4-Dioxane in Drinking Water using SPME Arrow–Trap with Multi-Step Enrichment

High-throughput Analysis of 1,4-Dioxane in Drinking Water using SPME Arrow–Trap with Multi-Step Enrichment

This application note showcases Solid Phase Microextraction (SPME) Arrow-trap technology, combined with multi-step enrichment (MSE) on the PAL3-Centri® platform and gas chromatography/mass spectrometry (GC/MS), to analyze 1,4-dioxane in water samples. The method successfully detects 1,4-dioxane at levels as low as 0.01 μg/L (10 ppt), surpassing the detection limits required by German REACH and US EPA regulations.

Determination of C2-C12 aldehydes in water by SPME Arrow on-fiber derivatization and GC/MS
Application Notes
Determination of C2-C12 aldehydes in water by SPME Arrow on-fiber derivatization and GC/MS
Determination of C2-C12 aldehydes in water by SPME Arrow on-fiber derivatization and GC/MS

Determination of C2-C12 aldehydes in water by SPME Arrow on-fiber derivatization and GC/MS

The method employing a SPME Arrow allows for the quantitation of water samples down to 50 ng/l for most of the described aldehydes with good precision.
A previous publication applying traditional standard SPME fibers and GC/MS achieved sensitivities down to 120-340 ng/l in spiked samples for C1, C3-C5

Quantification of nitrosamines in water by automated PAL SPME-Arrow and GC/MS
Application Notes
Quantification of nitrosamines in water by automated PAL SPME-Arrow and GC/MS

Quantification of nitrosamines in water by automated PAL SPME-Arrow and GC/MS

A method for the quantitative analysis of a number of different N-nitrosamines from aqueous samples has been worked out.

How to install the SPME MultiGuide in SPME Fiber Tools

SPME MultiGuide
Flyer

SPME MultiGuide

Easily switch form SPME Fiber to SPME Arrow without changing the Tool.

PAL3 Accessories & Smart Consumables
Brochures
PAL3 Accessories & Smart Consumables
PAL3 Accessories & Smart Consumables
PAL3 Accessories & Smart Consumables
PAL3 Accessories & Smart Consumables
PAL3 Accessories & Smart Consumables

PAL3 Accessories & Smart Consumables

Discover our Toolbox

PAL Smart SPME Arrow
Brochures

PAL Smart SPME Arrow

The Better SPME

Smart SPME Arrow Collection
Care & User (handling) Guides

PAL Smart SPME Arrow

General Information for PAL Smart SPME Arrows

SPME Arrow Conditioning Module
Manuals

PAL SPME Fiber Conditioning Module

Edition 5

Contact