Product Details

Micro-SPE Kit with PAL System uSPE Cartridges

PAL3-HW-uSPE54

µSPE Hardware Kit for PAL System uSPE Cartridges and PAL RTC
consisting of:

1 pc µSPE Liquid Tool D8/57 with Needle Guide for uSPE Cartridges
2 pcs Liquid Smart Syringe 1000 µl (SF1000-57-T-22-FL), gauge 22, flat tip
1 pc Tray Holder
2 pcs VT54 rack (PAL3-Rack-VT54)
1 pc µSPE Cartridge Tray, 54 position, aluminum
1 pc µSPE Elution Tray Cover, 54 position aluminum
1 pc Waste Receptacle with drain
4 pcs PAL System µSPE Cartridges for initial installation, 3-point teaching
USB stick with installation guide and scripts

(Requires PAL RTC System. Vials, caps and PAL System µSPE Cartridges need to be purchased separately)
PAL3-HW-uSPE54

Related Products

Vial-1.5-ND9-CG-100

Vial-1.5-ND9-CG-100

PAL System Vial 2CV, 1.5 ml, Clear Glass, Screw Caps
Cap-ND9-St-SP10Sb-100

Cap-ND9-St-SP10Sb-100

Magnetic Screw Cap for PAL System Vials 2CV,
Silicone/PTFE/Starbust-slitted septa 1.0 mm
Cap-ND9-St-SP10-100

Cap-ND9-St-SP10-100

Magnetic Screw Cap for PAL System Vials 2CV, Silicone/PTFE septa 1.0 mm
PAL3-Rack-Cart-uSPE54

PAL3-Rack-Cart-uSPE54

PAL System Cartridge Tray for 54 µSPE Cartridges
PAL3-TH-D857-uSPE

PAL3-TH-D857-uSPE

PAL System µSPE Syringe Tool for
250 -1000 µl Syringes, Needle Length 57 mm
PAL3-WashFast

PAL3-WashFast

PAL System Fast Wash Module
PAL3-HW-uSPE54

PAL3-HW-uSPE54

Micro-SPE Kit with PAL System uSPE Cartridges
PAL3-Vial-Lock-uSPE54

PAL3-Vial-Lock-uSPE54

PAL System uSPE Elution Tray Cover
PAL3-Wasterecept-uSPE

PAL3-Wasterecept-uSPE

PAL System uSPE Waste Receptacle with Drain
uSPE-GCQuE1-45-V

uSPE-GCQuE1-45-V

uSPE Cartridge - GC QuEChERS Sorbent Mix 1 - 45 mg - 01-05B, 108 pcs, [C18, PSA, MgSO4, GCB]
uSPE-GCQuE2-44-V

uSPE-GCQuE2-44-V

uSPE Cartridge - GC QuEChERS Sorbent Mix 2 - 44 mg - 01-19A, 108 pcs, [C18, PSA, MgSO4]
uSPE-GCQuE3-45-V

uSPE-GCQuE3-45-V

uSPE Cartridge - GC QuEChERS Sorbent Mix 3 - 45 mg - 01-14A, 108 pcs, [PSA, MgSO4]
uSPE-LCQuE1-30-T

uSPE-LCQuE1-30-T

uSPE Cartridge - LC & GC QuEChERS Sorbent Mix 1 - 30 mg - 01-03B, 96 pcs, [C18, Z-Sep, GCB]
uSPE-SAX-50-V

uSPE-SAX-50-V

uSPE Cartridge - Strong Anion Exchange (SAX) - 50 mg - 01-20A, 108 pcs

Related Content

ASMS 2025 - Fully automated implementation of EPA Method 1633 for LC-MS/MS analysis of PFAS in environmental samples using a customized robotic autosampler
Posters
ASMS 2025 - Fully automated implementation of EPA Method 1633 for LC-MS/MS analysis of PFAS in environmental samples using a customized robotic autosampler

ASMS 2025 - Fully automated implementation of EPA Method 1633 for LC-MS/MS analysis of PFAS in environmental samples using a customized robotic autosampler

  • Widespread use and persistence of PFAS has led to ubiquitous detection in water, soil, air, and living organisms.
  • US EPA Method 1633 is intended for analysis of PFAS in aqueous, solid and tissue samples using LCMS/ MS at part-per-trillion concentrations.
  • This method involves significant sample preparation and purification steps prior to instrumental analysis, leading to bottlenecks in sample processing.
  • We have developed a fully automated, online μSPE-LC-MS/MS workflow based on a customized LC TriPlus RSH SMART Advanced system for high-throughput analysis of PFAS in environmental samples following EPA Method 1633 guidelines
ASMS 2025 - Fully Automated Workflow for Volatile PFAS Analysis in Food Contact Materials Using GC-Triple Quadrupole
Posters
ASMS 2025 - Fully Automated Workflow for Volatile PFAS Analysis in Food Contact Materials Using GC-Triple Quadrupole

ASMS 2025 - Fully Automated Workflow for Volatile PFAS Analysis in Food Contact Materials Using GC-Triple Quadrupole

Gas Chromatography coupled with Triple Quadrupole Mass Spectrometry (GC/TQ) offers a robust and sensitive method for
detecting volatile PFAS. However, manual sample preparation could pose a bottleneck, impacting lab productivity. This study presents a robust and fully automated method using the PAL3 platform with GC/TQ for quantifying more than 30 volatile PFAS in FCMs, such as paper coffee cups. The automation approach minimizes human error, improving reliability
and reproducibility for routine analysis and safety assessments of PFAS in FCMs.

ASMS 2025 - Fully Automated Sensitive Quantitation of PFAS in Seafood for Regulatory Screening Using Triple Quadrupole LC/MS
Posters
ASMS 2025 - Fully Automated Sensitive Quantitation of PFAS in Seafood for Regulatory Screening Using Triple Quadrupole LC/MS

ASMS 2025 - Fully Automated Sensitive Quantitation of PFAS in Seafood for Regulatory Screening Using Triple Quadrupole LC/MS

Detecting trace PFAS level is challenging due to complex sample preparation like QuEChERS extraction followed by SPE cleanup, and evaporation/reconstitution. The manual steps can be labor-intensive and error-prone, affecting accuracy and reliability. This study developed a fully automated workflow for PFAS quantitation in seafood – shrimp.

Sample Preparation Compendium
eBooks

Sample Preparation Compendium

Automated, Green, and Efficient
A Compendium on Micromethods in Analytical Sample Preparation

Discover robust, precise, and reliable analytical methods while following the principles of Green Analytical Chemistry in various fields such as Food & Food Safety, Environmental, Clinical, Life Science, and Chemical.

The Power of Micro Solid Phase Extraction
eBooks
The Power of Micro Solid Phase Extraction
The Power of Micro Solid Phase Extraction

The Power of Micro Solid Phase Extraction

This eBook explores the potential of uSPE to transform analytical workflows. It highlights the key benefits of uSPE, compares it with traditional techniques and examines its application across various industries. This resource provides a comprehensive guide for scientists and lab managers looking to optimize their sample preparation processes, achieve higher precision and embrace sustainable practices in analytical chemistry.

QuEChERS Compendium
eBooks
QuEChERS Compendium
QuEChERS Compendium

QuEChERS Compendium

Automated uSPE cleanup for GC/MS or LC/MS analysis of pesticides and environmental contaminants in QuEChERS extracts of foods

PFAS Webinar
Webinars
Advancing PFAS Analysis - Robotic Automation and Streamlined LC/MS Workflows
Advancing PFAS Analysis - Robotic Automation and Streamlined LC/MS Workflows
Advancing PFAS Analysis - Robotic Automation and Streamlined LC/MS Workflows

Advancing PFAS Analysis - Robotic Automation and Streamlined LC/MS Workflows

To support the scientific community and advance PFAS analysis we are proud to offer a webinar on this topic.

Key topics:

  • PFAS Fundamentals: Learn about the chemistry and significance of PFAS compounds.
  • Sample Preparation Challenges: Understand current hurdles, regulations and best practices in PFAS extraction and purification.
  • Automated LC/MS Workflows: Get an overview on automated workflows and see how PAL System integrates with LC/MS to optimize sample preparation and injection.
  • Deep Dive: Explore online SPE for PFAS analysis.
Micro-SPE Webinar
Webinars
Advantages of automated and miniaturized uSPE clean-up in pesticides residues analysis
Advantages of automated and miniaturized uSPE clean-up in pesticides residues analysis

Advantages of automated and miniaturized uSPE clean-up in pesticides residues analysis

Recent developments in pesticides analysis extend the well-established methods to higher productivity and reliability while minimizing consumption and exposition to harmful chemicals. A workflow was developed that allows automatic preparation of calibration standards, automatic sample dilution, and automatic clean-up of sample extracts on one instrument, showing that miniaturized automated solutions are reducing errors, improving analytical consistency and protecting the environment in one convenient approach.

Presented by:

Thomi Preiswerk, Senior Account Manager, CTC Analytics AG

Gwen Lim , Specialist for automated sample preparation, CTC Analytics

Ederina Ninga, Postdoc, Research Group for Analytical Food Chemistry, Danish Technical University 

 

Automated Sample Preparation webinar
Webinars
Automated Sample Preperation for LC/MS and GC/MS - Solutions for Food and Environmental Analysis
Automated Sample Preperation for LC/MS and GC/MS - Solutions for Food and Environmental Analysis

Automated Sample Preperation for LC/MS and GC/MS - Solutions for Food and Environmental Analysis

In this presentation we want to discuss an important development and a demand from analytical laboratories about the standardization and the automation of sample preparation procedures for food safety, environmental, the forensic or pharmaceutical analysis.

Presented by:
Hans-Joachim Huebschmann, PhD

High-Sensitivity PFAS Determination in Seafood
Application Notes
High-Sensitivity PFAS Determination in Seafood

High-Sensitivity PFAS Determination in Seafood

This application note showcases a fully automated workflow for the precise quantification of 73 PFAS in seafood. Utilizing a PAL RTC autosampler and Agilent triple quadrupole LC/MS system (LC/TQ), the method automates calibration, QuEChERS extraction, and μSPE clean-up.

Analysis of Highly Polar Pesticides
Application Notes
Analysis of Highly Polar Pesticides
Analysis of Highly Polar Pesticides

Analysis of Highly Polar Pesticides

Micro-SPE (uSPE) emerged as an automated green micromethod for sample preparation and clean-up in food safety, proteomics, forensic, environmental and analysis since more than ten years. Applications are wideranging and cover drugs, environmental contaminants, and, in particular, the extract clean-up in multiresidue pesticide analysis. The automation of the uSPE sample preparation steps led to the desired standardization of the applied sorbent materials for extract clean-up for the large variety of food commodities, an increase in sample throughput, and the welcome potential for offline and online hyphenation with GC/MS, LC/MS or even IC analysis.

Routine Pesticide Analysis using micro-SPE
Application Notes
Routine Pesticide Analysis using micro-SPE

Routine Pesticide Analysis using micro-SPE

This report presents for the first time the application of uSPE for the clean-up of the raw extracts using ethyl acetate as extraction solvent for pesticides from different also more complex food commodities.

How to use PAL Method Composer

Walk away QuEChERS extracts clean-up

See this detailed video of the uSPE workflow for the clean-up of raw pesticides extract. The PAL uSPE Cartridge is operated in scavenger mode eluting the pesticides in a clean extract. The matrix is kept on the sorbent material. The cleaned extract can be injected without waiting time online for LC/MS or GC/MS analysis. All samples are treated on the same time axis for highest reliability.

Minimize PFAS Background with PAL System Upgrade Kits
Brochures

Minimize PFAS Background with PAL System Upgrade Kits

Equip your PAL Systems for PFAS Analysis with Upgrade Kits and minimize PFAS Background.

PAL Method Composer
Brochures

PAL Method Composer

Methods in minutes

PAL3 Accessories & Smart Consumables
Brochures
PAL3 Accessories & Smart Consumables
PAL3 Accessories & Smart Consumables
PAL3 Accessories & Smart Consumables
PAL3 Accessories & Smart Consumables
PAL3 Accessories & Smart Consumables

PAL3 Accessories & Smart Consumables

Discover our Toolbox

Fully Automated QuEChERS Extraction and µSPE Clean-up of Organophosphate Pesticides in Orange Juice
Publications
Fully Automated QuEChERS Extraction and µSPE Clean-up of Organophosphate Pesticides in Orange Juice

Fully Automated QuEChERS Extraction and µSPE Clean-up of Organophosphate Pesticides in Orange Juice

Chiew Mei Chong1, Hans-Joachim Hübschmann2

1 CTC Analytics Pte. Ltd., Singapore.
2 HANS Analytical Solutions, Osaka, Japan.

Contact